The ice manufacturer line to my fridge presently doesn’t have shutoff valve and I also’d choose to include one but i can not determine what size the connector is

we bought a 1/4 inch valve considering that the ice maker connector We have says 1/4 FCM it did not fit on it but. It seems similar to 1/8 inches, however a 1/8 inches valve does not fit either, even though it is quite mail order bride near. Where am I able to find information regarding water pipeline sizes, there has to be some standard?

The copper water line i will be linking it to gets the precise exact same dimension as the refrigerator.

IMPROVE:

Okay I was thinking that looking the net for 1/4″ OD Valve Male Female would get me personally the thing I require but i will be getting no total outcomes therefore I’ve reopened issue! Can anybody provide me personally a web url to an item which will fit? i have added an image of this present connection where let me include the valve. Many Thanks!

3 Responses 3

You can find various criteria to pipelines and threads. Your problem is you want to mix two various threaded requirements.

The ball valve which you connected to has nationwide pipeline threads (NPT). NPT are tapered plus it is the fact that taper that produces the seal between a female and male joint. No washers are needed.

What exactly is shown in your picture is compression fixtures that have a right or operating thread. The seal is created by either a ferrule or even a plastic washer.

For you personally, the text between your copper pipe and also the supply hose happens to be made the following:

1/4″ Copper Tube > 1/4″ Compression by 1/4″ Compression Coupling > 1/4″ Supply Hose

The seal on the copper pipe is created with a ferrule that is situated underneath the nut. Given that nut is tightened, the ferrule is compressed between the coupling additionally the pipeline.

The seal on the supply hose part is created by way of a plastic washer that will be frequently integral the the nut regarding the supply hose. (The compression coupling could have include two pea pea pea pea nuts, certainly one of which includes been discarded due to the fact supply hose has one integral.)

Therefore, to resolve your concern, you simply require a 1/4″ compression x 1/4″ compression valve that may change the present coupling. Listed here is a web link to this type of valve.

Do the paperwork is had by you that was included with the refrigerator? It must show the ice maker install and say the size maybe associated with valve. I’ve constantly seen that it is 1/4″.

Where could be the water line tapped from? Often it comes down a 1/2″ copper pipeline. You might place your valve from the copper pipeline part.

EDIT: web Page 33 of this installation manual states that the water supply pipe is 1/4″ OD. you will need a 1/4″ valve. Make sure there are not any burrs regarding the copper tubing after you cut it. Often you’ll want to register the sides. In the event that pipeline cutter just isn’t razor- sharp it may mushroom the ends which will ensure it is appear that it’s perhaps not the right diameter.

On it, preferably set in the wall in plastic box if you have more time and money, the best thing is to run either a 1/2 inch copper line or a 1/2 galvanized line to the back of your refrigerator with a 1/4 inch connection. An alternative cheaper means would be to run a 1/4 inches line through the 1/4 inches connection at your double shut off valve using your drain. But, the copper line is really a line that is hard it gets crimped particularly when you or somebody else is careless in going the refrigerator around to completely clean or any.

Making use of two crescent wrenches, some tips about what to complete in the event that you currently have a copper that is hard to your straight back without a shut down valve anywhere in web web site. You should buy a kit which includes the right components you need, 1/4 inches connectors having a 6 base, 1/4 inches supply hose, with the 1/4 pea pea nuts on both ends. Carefully take action your self or get yourself a plumber to slice the copper line with a copper pipeline cutter, a good clean cut, a few of ins this part of where in actuality the line is released of wall or case (so long as it is not crimped, you are ok to cut it).

Place the free 1/4 inches nut on backwards in the pipeline, so that the nut covers the ferrel tucked in during the side of the final end associated with pipeline, then, screw regarding the 1/4 inches connector/adjuster into it, aided by the 1/4 inches threads into the 1/4 inches nut in the hose, and tighten up, snug, never ever overbearing, ever with any plumbing system. Then link one other end of hose/nut into the threaded end on the fridge in the bottom, snug! Keep In Mind! But, a good thing to accomplish whenever you are linking a line to either a tap or refrigerator or in any case might be, just before put that final connection from the fridge, put that result in a huge bucket and turn it in to clear the type of atmosphere and grub, because that knows the length of time it has been sitting. Plus, if you have atmosphere into the lines, that is a entire nother hassle, trust in me you will not want! Obtain the fresh air away! you certainly can do all this yourself too! Don’t neglect to always check every thing for leakages! Best of luck! Now get commemorate you simply stored your self $150.